Page 18
Operation
TMC-6700/1000 Series Progressive Scan CCD Digital Color Camera
The mathematical transformation is a linear-space 3 x 3 matrix operation, as shown below.
The coefficients have been optimized for the spectral sensitivities of a Bayer CFA (color filter array).
For camera systems, a linear-space color correction matrix is used. The coefficients are programmable
through the serial interface.
3.3.4 User-Programmable Functions
3.3.4 (a) Edge Enhancement (Sharpness)
Edge enhancement is set by RS-232 control. Horizontal, vertical, and both H and V enhancement are
selectable. The DSP mathematically manipulates the horizontal and vertical edge information to
sharpen the image. The intensity of the enhancement can be set by Edge Enhancement Level.
3.3.4 (b) Gamma Selection
You can toggle between 0.45 (default) and 1.0 (linear output) by either the switch on the rear panel or
RS-232 control.
3.3.4 (c) Shutter Selection
The TMC-6700/1000 series provides manual shutter and asynchronous shutter with external trigger
(VINIT). Each mode is selectable up to 1/16,000 sec. By selecting the shutter dial setting (0 to 9), the
preset shutter duration is loaded from RAM.
The TMC-6700/1000 series also supports Direct shutter mode. In Direct shutter mode, the user can
control any exposed line count within the shutter time range.
3.3.4 (d) RGB to YCrCb Conversion
The TMC-6700/1000 series can output three different digital video outputs, 24-bit RGB, 24-bit 4:4:4
YCrCb, and 16-bit 4:2:2 YCrCb. Output can be selected by software interface only.
YCrCb conversion is expressed in the following formula:
Y = 0.257R + 0.504G + 0.098B + 16
Cr = 0.439R + 0.368G - 0.071B + 128
Cb = -0.148R - 0.291G + 0.439B + 128
3.3.4 (e) User Parameter Saving and Loading
User parameters can be stored in EEPROM. However, the user has no direct read/write access to the
EEPROM. RS-232 software permits read/write of the parameters to RAM. Four RAM banks are
available; if the user needs to save the data permanently into EEPROM, then all of the data in the four
Ro
Go
Bo
1.75 0.25–0.5–
0.1875– 1.3125 0.125–
0.125–0.5– 1.625–
Ri
Gi
Bi
=