4.3 TMC-7 ADJUSTMENT PROCEDURES
4.3.1 PRESET
Note: The following controls for the external control
board can be accessed by removing the access port on
the left side of the TMC-7. All other presets and
adjustments are accessed by removing camera cover.
Preset each potentiometer as follows:
Matrix board
VR1 MGC = 2.5 V
VR2 W/B (Hue) = 4.0 V
Driver Board
VR2 AGC = 2.0 V
VR1 AGC MAX = 3.0 V
Auto-White Balance Board
VR6 B LEVEL = 3.4 V
VR7 SHP LEVEL = 3.4 V
VR1 CHR LEVEL = 2.3 V
VR2 R-Y HUE = 3.5 V
VR3 B-Y HUE = 3.0 V
VR4 B-Y GAIN = 2.4 V
VR5 R-Y GAIN = 3.2 V
VR14 Y1 GAIN = 2.0 V
VR8 Y LEVEL = 3.0 V
VR9 SET UP = 3.0 V
VR12 C1 GAIN = 3.4 V
VR11 B GAIN = 4.0 V
VR10 R GAIN = 4.0 V
VR15 YH GAIN = 3.2 V
VR16 VAP GAIN = 1.8 V
VR17 VAP SLICE = 1.5 V
VR18 HOLE = 2.0 V
Jumper setting
W2 Open (factory setting)
4.3.2 FUNCTION TEST
With above settings, the camera will output a good
picture and you can proceed to the fine tuning process.
4.3.3 WHITE BALANCE
Equipment: Color bar chart (3200°K),
Vector scope, Wave form monitor.
Set AGC and White balance switches to Manual side
(push down ).
Use standard Fujinon lens (Calibrated ) and set the iris
to F=8.
Burst level
Adjust VR6 so that burst level on Vector scope is on the
75 % line or 286±15mV. If Burst vector is not stable, add
a 22pf capacitor to crystal capacitor. Make sure to select
the right value of C5 located at Driver board.
4.2 PREPARATION
4.2.1 MECHANICAL BACK FOCUS
ADJUSTMENT
Subject: Resolution chart
1. Mount the manual lens (i.e. Cosmicar 25mm,
F=1.4).
2. Open the lens iris completely and set lens focal
length to minimum for the lens used (e.g. 2 ft.).
3. If image is not focused properly, set back focus as
follows.
4. Unscrew the M2x3 hex screw on the Front Panel
until the focus ring is loose.
5. Adjust the silver back focus ring until the image is
focused.
6. Repeat steps 4 and 5 if needed.
Back Focus Ring
Back Focus
2 Feet
7