Operation
TM-4000CL Series Progressive Scan Shutter Cameras
Model: TM-4000
Operation Mode: Dual Tap Output
Full Scan
14.79 Frames/second
Master Clock: 80.000 MHz, M= 12.5 nsec
Pixel Clock: 40.000 MHz, P= 25.0 nsec
3. External Reset Timing and Vertical Signals Timing
4. Async Reset Timing
External VD
Internal VD
FDV
Digital Data
Analog Video
VINIT Trigger
Internal VD
FDV
Digital Data
Analog Video
A [ 2080 H], (67.6 msec)
B [ <1 H], ( <32.5 µs)
C [ 9 H], (0.29 ms)
D [ 2071 H], ( 67.3 ms)
E [ 2080 H], ( 67.6 ms)
F [ 0 H], ( 0.0 µs)
I [ 0 H], ( 0.0 µs)
L [ 3H], ( 97.5 µs)
P [ 3H], ( 97.5 µs)
G [ 32 H], ( 1.04 ms)
J [ 32 H], ( 1.04 ms)
M [ 29 H], ( 0.94 ms)
N [ 3H], ( 97.5 µs)
H [ 2048 H], ( 66.56 ms)
K [ 2048 H], ( 66.56 ms)
O [ 2048 H], ( 66.56 ms)
S [ 2071 H], ( 67.3 ms)
T [ 2080 H], ( 67.6 ms)
Y [ 2048 H], ( 66.56 ms)
CC [ 2048 H], ( 66.56 ms)
Q [VariableH], ( µs)
AA [ 29 H], (0.94 ms)
X [ 32 H], ( 1.04 ms)
BB [ 3 H], ( 97.5 µs)
Z [ 3H], ( 97.5 µs)
R [ 9 H], ( 0.29 ms)
V [ 32 H], ( 1.04 ms)
Q: Internal VD shift = 1H + async shutter speed
W [ 2048 H], ( 66.56 ms)